publicCanada — Englishexpand_more
SPECS CURRENT: 2025 REV 04
water_dropMUNICIPAL & INDUSTRIAL UTILITIES DIVISION

High-Integrity Flow Control for Municipal & Industrial Water Infrastructure

Engineered valve, pump, and filtration assemblies designed for zero-cavitation raw water intake, abrasive sludge transport, chemical metering, and potable distribution under AWWA C504, NSF/ANSI 61, and ISO 9001 compliance standards.

LIVE RECLAMATION FACILITY

450 MGD Treatment Plant Automation Array

RELIABILITY INDEX
> 450k hrs

Mean Time Between Failures

SEALING INTEGRITY
Class VI

Zero Bubble-Tight Resilient Seat

BORE RANGE
2" to 72"

DN50 – DN1800 Municipal Standard

RATED WORKING HEAD
PN40

Max 40 Bar System Pressure

PROCESS BLUEPRINT

End-to-End Water Flow System Architecture

Select a processing unit below to evaluate critical valve trims, cavitation mitigators, and pump actuation requirements.

schemaISO 14001 / AWWA M44 ARCHITECTURE
STAGE 01 PARAMETERSSTANDARD: AWWA C504 Class 150B

Raw Water Intake & Deep Well Lift Systems

Submersible turbine pumps, coarse trash racks, and dual-plate silent check valves designed for harsh abrasive river gravel, debris diversion, and turbulent flow prevention during high seasonal run-offs.

SPECIFIED HARDWARECV-120-W Check + WVP-500
MAX FLOW VELOCITY5.2 m/s (17.1 ft/s)
CORROSION CLASSISO 12944 C5-M Marine
View Mapped Stage Productsarrow_downwardcheck_circleCavitation Tested to EN 60534-4
STAGE HYDRAULIC HEAD-LOSS CURVEDN600 BENCHMARK
Dynamic Knee: 1.4 Bar LossHead (m)Flow Q (m³/h)
info

Critical check valve closure time must not exceed 0.12 seconds to avoid secondary elastic pressure wave reverberation.

VALVEX WATER DIRECTORY

Municipal & Treatment Plant Valve Portfolio

Engineered assemblies certified for continuous immersion, potable safety, and aggressive slurry resilience.

SHOWING: ALL 5 WATER FAMILIES
POTABLE AWWANSF/ANSI 61
MODEL RSV-150W

AWWA C504 Resilient-Seated Butterfly Valves

Engineered for distribution lines, filter galleries, and pump isolation with full field-replaceable vulcanized seats.

Size Bore Range:DN80 – DN1800 (3" – 72")
Pressure Rating:PN16 / Class 150B / 250 psi
Seat & Liner:EPDM / NBR Food Grade
View Specifications
PUMP ROTODYNAMICIE3 PREMIUM
MODEL WVP-500

Non-Clog Dry Pit Submersible Pumps

Large passage vortex handling raw unscreened municipal wastewater, rags, and fibrous debris without clogging.

Solids Spherical:100mm (4") Free Passage
Max Flow Capacity:2,800 m³/h (12,300 GPM)
Motor Rating:Up to 315 kW / 400V 50/60Hz
View Specifications
ISOLATION AWWAAWWA C515
MODEL RWG-200

Resilient Wedge Gate Valves

Non-rising stem ductile iron gate valves with EPDM encapsulated wedge for drop-tight bi-directional isolation.

Size Bore Range:DN50 – DN600 (2" – 24")
Cold Working Press:250 psi / PN16 / PN25
Internal Coating:Fusion-Bonded Epoxy >250µm
View Specifications
ANTI-SURGEFAST SHUT: 0.1s
MODEL CV-120-W

Dual Plate Spring-Assisted Check Valves

Dynamic fast-acting non-slam design preventing hydraulic shock waves and backflow surge damage to lift pumps.

Size Bore Range:DN50 – DN1200 (2" – 48")
Pressure Range:PN10, PN16, PN25, PN40
Spring Mechanism:Inconel X-750 Torsion
View Specifications
SLURRY SEVEREZERO LEAKAGE
MODEL KGV-400

Heavy-Duty Sludge Knife Gate Valves

Full-port beveled blade slicing through fibrous solids, thickened secondary sludge, and grit chamber effluent.

Bore Diameter:DN50 – DN900 (2" – 36")
Liner Compound:Polyurethane / Natural Rubber
Blade Material:316L / 17-4PH Hardened SS
View Specifications
build_circleBESPOKE VALVE SKIDS

Require Custom Sizing or Non-Standard AWWA Flange Drill?

Our engineering bureau in Edmonton and Houston provisions pre-assembled actuated manifolds, telemetry-ready valve vaults, and bypass loops.

check_circleASME B16.42 / AWWA C110 compatibility
check_circleModbus / Profibus / HART direct interface
FIELD CAPABILITIES

Sector-Specific Water Engineering Services

From transient pipeline surge calculations to certified potable recoating, our specialized teams protect water assets from premature failure.

waves

Hydraulic Transient & Water Hammer Analysis

Numerical Joukowsky pulse modeling, surge chamber volume sizing, and dynamic fast-acting check valve closure optimization to suppress pipeline bursts.

  • › Bentley HAMMER simulation
  • › Air release sizing calculation
  • › Site pressure telemetry audits
verified

Potable Water Lining & Recoating Certifications

Turnaround abrasive grit blasting to SSPC-SP 10 with certified application of NSF/ANSI 61 and WRAS approved 100% solids solvent-free epoxy barriers.

  • › Holiday spark testing (NACE SP0188)
  • › DFT ultrasonic mapping
  • › Zero VOC compliant coatings
settings_input_component

Turnaround Actuation Retrofits & Upgrades

Direct field conversion of obsolete manual gearboxes to intelligent multi-turn or quarter-turn electric actuators with digital battery-backup fail-safes.

  • › AUMA & Rotork integration
  • › ISO 5211 custom bracket forging
  • › Live plant hot-tap changeouts
EMPIRICAL FIELD DATA

Engineered Case Studies & Technical Reports

Documented performance records showing measurable reductions in head-loss energy consumption and downtime prevention.

FORMAT: PDF TECHNICAL DOSSIERS
CASE 01MUNICIPAL CLEAN WATER UPGRADE•LOCATION: GREAT LAKES BASIN

Metropolitan Water Reclamation District: 450 MGD Filter Gallery Modernization

Replaced 128 leaking metal-seated gate valves with custom vulcanized-seat VALVEX RSV-150W butterfly units. The retrofit eliminated transient water hammer chatter during automated filter backwashes and dropped pumping energy consumption by 14.2% across four distribution quadrants.

trending_down-14.2% Parasitic Pumping Loss
verified_userZero Unscheduled Leaks (36 Mos)
savings$410,000 / Yr Operating Savings
descriptionDownload Project Whitepaper (PDF 4.2MB)
CASE 02WASTEWATER SLURRY / DIGESTION•LOCATION: CALGARY REGIONAL UTILITY

Regional Biosolids Pipeline: Mitigating 18% Dry Solids Slurry Abrasion

Conventional ductile knife gates experienced severe packing blowout and seat scoring every 4 months due to silica sand entrainment. VALVEX installed KGV-400 valves equipped with ceramic-infused polyurethane sleeve seats, successfully exceeding 5 years of continuous MTBF under 12 Bar pulsing feed.

update5-Year Extended MTBF
shield100% Zero Cavity Packing Retention
tunePneumatic Double-Acting Trim
descriptionDownload Slurry Study (PDF 3.8MB)
CASE 03SEAWATER DESALINATION (SWRO)•LOCATION: RED SEA INTAKE COMPLEX

Desalination Intake Facility: Super Duplex 2507 Assemblies for 42,000 ppm Chlorides

Deep intake headers required immunity to high-temperature hyper-saline crevice attack. VALVEX engineered triple-offset disc closures utilizing Super Duplex UNS S32750 metallurgy with Stellite Grade 21 hardfacing, with zero pitting corrosion detected over 48,000 operational duty hours.

check_circlePREN > 42 Metallurgy
science42,000 ppm Cl- Tested
speedClass 300 (PN50) Operating Head
QA AUDITS & VERIFICATION

Stamped Water Sector Compliance Matrix

Every VALVEX water component is serialized, factory hydrostatic test-stamped to ISO 5208, and accompanied by EN 10204 3.1 material test certificates.

verifiedANNUAL ACCREDITATION VERIFIED: 2025
AWWAtask_alt

AWWA C504 / C515

Rubber-seated butterfly & gate standard.

STAMPED CERT
NSF / ANSIhealth_and_safety

NSF 61 & 372

Potable drinking water health effects & zero-lead.

STAMPED CERT
WRAS UKcheck_circle

WRAS Material

BS 6920 non-metallic water contact suitability.

STAMPED CERT
ISOnature

ISO 14001:2015

Environmental management & lifecycle compliance.

STAMPED CERT
PED EUgavel

PED 2014/68/EU

Category III/IV pressure equipment directive.

STAMPED CERT
CRNinventory_2

Canadian CRN

All provinces registered Category 0C fittings.

STAMPED CERT
support_agentDIRECT APPLICATION DESK

Speak Directly with a Municipal Water Application Specialist

Submit your process P&ID, flow conditions, head-loss envelope, or custom flange schedule. Receive an engineered valve schedule and quote package within 24 operational hours.

phone_in_talk1-800-555-FLOW ext 402
scheduleEdmonton (MST) & Houston (CST)

Fast RFQ Water Spec Form

Direct transmission to lead application engineers